Tytuł
-
Analyse retard des mesures de temperatures
-
Wariant tytułu
-
Delayed response analysis by means of the temperature measurements. Application to the leakages detection
Zastosowanie analizy odpowiedzi opóźnionej w pomiarach temperatury ziemnych obiektów hydrotechnicznych do identyfikacji przecieków
-
Autor
-
Radzicki, Krzysztof
-
Promotor
-
Stéphane Bonelli
-
Promotor pomocniczy
-
Jerzy Szczęsny
-
Data wydania
-
2008
-
Data obrony
-
04.05.2009
-
Wydawca
-
[s.n.]
-
Język
-
francuski
-
Słowa kluczowe
-
digue,barrage, érosion interne, fuite, fonction de la réponse impulsionelle, thermométrie, diffusion, advection, transport couplé du chaleur et de l'eau
embankment, levee, dam, internal erosion, leakage, impulse response function, thermometry, diffusion, advection, coupled heat and water transport
wał, zapora, erozja wewnętrzna, przeciek, funkcja odpowiedzi impulsowej, thermometria, dyfuzja, adwekcja, sprzężony transport ciepła i wody
-
Abstrakt
-
L’érosion interne est l’une des causes majeures de rupture des digues et des barrages. Le développement des processus érosifs est lié au changement de différents paramètres du milieu poreux, particulièrement ses paramètres hydrauliques. L’objectif du travail de thèse est le développement de la possibilité d’identification des fuites, ainsi que l’identification des valeurs de paramètres physiques du milieu thermo-hydraulique du corps d’ouvrages hydrauliques en terre, par l’analyse des mesures de la température naturelle du remblai. Le problème concerne les phénomènes de diffusion, et le couplage entre écoulement d’eau et transfert thermique (advection). A partir de résultats de simulations numériques, on décrit l’influence thermique de l’érosion régressive sur le champ de la température du corps d’ouvrage hydraulique, et on présente les paramètres caractéristiques qui permettent d’identifier sa cinétique. On élabore un modèle de réponse impulsionelle, physiquement fondé, pour la thermométrie d’auscultation. Il permet d’analyser les mesures de température, et d’en déduire des informations quant aux écoulements d’eau dans le corps de l’ouvrage. En cas de milieu poreux homogène, une signification physique aux paramètres du modèle permet de les exprimer en fonction de données géométriques, du nombre de Péclet et par suite de la vitesse d’écoulement de l’eau. Le modèle est validé par des modélisations numériques ainsi que par des mesures in situ.
Internal erosion is one of the main reasons of the dams and dikes collapses. Progress of the erosion process is linked to the change of different parameters values of the porous medium, especially of its hydraulic parameters. The goal of this Ph.D. thesis is the development of the possibility of leakages identification as well as the identification of some parameters values of the thermo-hydraulic medium that is the body of the earth hydraulic work, by an analyze of the natural temperature measurements in the embankment. The problem concerns diffusion processes and coupled transport of heat and water. The thermal influence of the regressive erosion on the temperature distribution inside the hydraulic work body is described. We present also its characteristic parameters which allow identifying its kinetic. A model of impulse response function, with physical justification, is developed for thermometry monitoring. It allows analyzing the series of the temperature and deducing the information concerning the water flow in the embankment. Because of the physical explication of the model parameters, in the case of a porous saturated medium, the model allow to calculate the Peclet number and the water velocity in function of the geometry of the construction. The model was validated by numerical simulations and in situ measurements.
Erozja jest jednym z głównych powodów katastrof wałów i zapór. Rozwój procesów erozyjnych jest związany ze zmianą parametrów fizycznych ośrodka porowatego, w szczególności jego parametrów hydraulicznych. Celem pracy jest rozwinięcie możliwości identyfikacji przecieków jak również oszacowanie wartości wybranych parametrów ośrodka termiczno-hydraulicznego ziemnego korpusu obiektu piętrzącego, poprzez analizę pomiarów jego temperatury. Analizowany problem związany jest z zagadnieniami dyfuzji oraz sprzężonego transportu ciepła i wody (adwekcja). Analiza wykonanych modelowań numerycznych pozwoliła opisać wpływ erozji wstecznej (nierozwiniętego w pełni przebicia hydraulicznego) na pole temperatur w korpusie obiektu piętrzącego jak również wskazać jego charakterystyczne parametry które umożliwiają oszacowanie kinetyki jego rozwoju. Przedstawiono model bazujący na teorii funkcji odpowiedzi impulsowej, wraz z jego uzasadnieniem fizycznym, służący analizie pomiarów temperatury. Można dzięki niemu otrzymać informacje dotyczące przepływu wody w korpusie obiektu w tym przede wszystkim określić lokalizację przecieków. W przypadku ośrodka homogenicznego identyfikacja fizycznego znaczenia parametrów modelu pozwala oszacować wartość liczby Pekleta oraz prędkość filtracji w oparciu o geometrię obiektu. Model został zweryfikowany w oparciu o modelowania numeryczne oraz pomiary zrealizowane na dwóch rzeczywistych obiektach.
-
Klasyfikacja PKT
-
271951 Geofizyka stosowana (metody pomiarów wielkości fizycznych w geologii, hydrogeologii, geologii inżynierskiej i poszukiwaniu złóż kopalin użytecznych)
621900 Śródlądowe budownictwo hydrotechniczne
620000 Gospodarka wodna
271900 Geofizyka (litosfery)
270000 Nauki geologiczne
-
Wydział
-
Wydział Inżynierii Środowiska i Energetyki
-
Licencja
-
-
Prawa dostępu
-
Zasób dostępny dla wszystkich