An analysis of the application of the Alden turbine ‒ a case study of the Dobczyce hydroelectric power plant
Variant of the title
Analiza zastosowania turbiny Aldena na przykładzie hydroelektrowni Dobczyce
Author
Twaróg, Bernard
Published in
Technical Transactions
Numbering
Y. 112, iss. 1-Ś
Pages
147-156
Release date
2015
Place of publication
Kraków
Publisher
Wydawnictwo PK
Language
English
DOI
10.4467/2353737XCT.15.193.4398
Keywords
Alden turbine, Kaplan turbine, power plant modelling
turbina Aldena, turbina Kaplana, modelowanie pracy elektrowni wodnej
Abstract
This study contains an analysis of the Alden turbine with a power level of 5.0 MW in the Dobczyce power plant. Taking into account results of annalysis, it may be concluded that the contemplated use of the Alden turbine in the Dobczyce power plant is close to the limits of practical applicability and economic viability of this solution. The average annual energy output value achieved using the Kaplan turbines oscillates around 9 GWh, and if the turbines are replaced with an Alden turbine, the estimated average annual output may reach a maximum of 10.6 GWh which represents an increase in power output of about 17%.
W pracy zaprezentowano analizę możliwości wykorzystania turbiny Aldena o mocy 5 MW w elektrowni Dobczyce. Uwzględniając uzyskane wyniki analizy, należy zauważyć, że zastosowanie turbiny Aldena jest na granicy technicznej możliwości oraz ekonomicznej efektywności. W dotychczasowej konfiguracji z turbinami Kaplana elektrownia średniorocznie produkuje 9 GWh. Przy zastosowaniu turbin Aldena produkcja mogłaby wzrosnąć do kilkunastu procent.
PKT classification
920000 Kształtowanie i ochrona środowiska
620000 Gospodarka wodna
Department
Faculty of Environmental and Power Engineering
License
Licencja PK
Access rights
Zasób dostępny dla wszystkich
Cookies or other similar solutions are used on the page. Take a look at privacy policy to get to know the details.