Abstrakt
Examples of defectively constructed-designed and constructed openings in RC beams in a building under construction were presented in the paper. As a result of errors in the design and construction-construction phases, the beams could not fulfil their function. The state of the considered beam with openings was defined as critical (a failure). The results of an analysis of the designed and constructed-constructed state showed differences in the static performance of the structure. However, the redistribution of internal forces is not significant because of the relatively stiff floor slab which takes over the loads from beams. This paper can also provide a background for a more general discussion about the present quality of coordination between design and construction of building structures.
W artykule przestawiono przykłady błędnie wykonanych otworów w belkach żelbetowych nowo wznoszonego budynku. Na skutek błędów projektowo-wykonawczych belki nie mogły spełniać swojej funkcji. Stan analizowanej belki z otworami określono jako awaryjny. Wyniki obliczeń stanu projektowanego i istniejącego wykazały różnice w pracy statycznej konstrukcji. Redystrybucja sił wewnętrznych nie jest jednak znacząca z powodu zastosowanej względnie sztywnej płyty stropowej, która przejmuje na siebie obciążenia z belek.