Shear connections have to transfer forces between structural members – steel and concrete with an adequate degree of safety. The distributions of horizontal shear resistance within steel – – concrete structures will be described depending on material characteristics of steel and concrete components in Bison project. Laboratory tests provide the only practicable basis for specifying safety margins for ultimate strength of shear connections in steel – concrete beams. The determination of partial safety factors within shear connections will be presented according to EC4 and EC0 (EN 1990). Particulary, safety factors of shear stud capacity in full composite connections will be analised.
Przy projektowaniu belek stropów o konstrukcji zespolonej niezbędne jest określenie wartości charakterystycznej i obliczeniowej parametrów wytrzymałościowych. Wartości wytrzymałościowe połączeń elementów stalowych z płytą żelbetową są zależne od wielu parametrów losowych. Wpływ tych czynników losowych jest uwzględniony przy obliczaniu częściowego współczynnika bezpieczeństwa.